Compressor overhauling

Compressor is Overheating

Screw compressors may overheat due to many reasons.Some of these reasons:
1.      Make sure that the room in which your compressor is running is ventilated properly. If your compressor is running in a closed or constricted environment, rising ambient temperature may cause your compressor to overheat.
2.      Direct the ejected hot air from the radiator of your compressor to outside of the compressor room. Doing so will prevent hot air flow into the compressor and will decrease the ambient temperature.
3.      Make sure that the compressor is not exposed to sunlight in hot seasons.
4.      If the panel filter located at the top of your compressor is stuffed, the fan cannot cool the radiator and overheating will occur.
5.      If the radiator is clogged, airflow will not be possible through the radiator core and overheating will occur.
6.      Any blockage that may occur in the inner piping of the compressor will prevent oil circulation and the compressor will overheat.

Major Part of Compressor servicing


  • Lubricant
  • Thermal Valve
  • Dirt in the Filter
  • Unclean Cooling Fan
  • Separator Damage.
  • Bearing